Data Center Infrastructure Resource Guide

Data centers are the "nerve centers" of the modern economy, housing the critical IT infrastructure that enables organizations to conduct business around the clock and around the world. Anixter’s Data Center Infrastructure Resource Guide is a comprehensive reference document designed to help professionals design…
A Comprehensive Reference
Data centers are the "nerve centers" of the modern economy, housing the critical IT infrastructure that enables organizations to conduct business around the clock and around the world. Anixter’s Data Center Infrastructure Resource Guide is a comprehensive reference document designed to help professionals design, build, and manage these specialized, mission-critical environments. This article summarizes the key content from this essential guide.
Why This Guide Matters
Data centers are unique, "hardened" facilities dedicated to providing uninterrupted service to business-critical data processing operations. They demand:
- 7×24×365 availability with fail-safe reliability and continuous monitoring.
- Power management and network communications with redundancy and path diversity.
- Network security, physical access control, and video surveillance.
- Zoned environmental control and sophisticated fire suppression systems.
The guide serves as a desktop resource, providing standards-based best practices to navigate the complexities of data center design, from power and cooling to cabling infrastructure and security. It is structured into five main sections, covering everything from the basics of what a data center is to key considerations for deploying solutions.
Section 1: Introduction to Data Centers
What is a Data Center?
A data center is a facility that centralizes and consolidates Information Technology (IT) resources. It provides the infrastructure for server consolidation, business continuity, database management, eBusiness, and many other initiatives. Data centers fall into two major categories:
- Corporate Data Centers (CDCs): Owned and operated by private corporations, institutions, or government agencies to support their own data processing and Web-oriented services.
- Internet Data Centers (IDCs): Owned by commercial operators (telcos, service providers) to provide outsourced IT services like Web hosting, colocation, managed servers, and content distribution on a commercial basis.
Common Attributes of All Data Centers
Despite differences in scale, both CDCs and IDCs share common functions, including:
- Internet access and wide area communications.
- Application hosting and content distribution.
- File storage and backup.
- Failsafe power and adequate HVAC.
- High-performance cabling infrastructure.
- Security (access control, video surveillance).
Section 2: Data Center Design Considerations
Professional Engineering and Power Requirements
Successful data center design begins with professional engineering due to the complex coordination of HVAC, electrical, mechanical, and telecom trades. The guide notes that data center power consumption has skyrocketed, doubling between 2003 and 2006, driven by the adoption of blade and 1U servers. As a result, the traditional rule of thumb for power planning has evolved from "watts per square foot" to "watts per cabinet".
Cooling
High-density servers generate significant heat, creating a major cooling challenge. The guide emphasizes the importance of hot aisle/cold aisle cabinet configurations, as recommended by ASHRAE and ANSI/TIA-942. Key practical measures include:
- Cabinet Configuration: Arrange cabinets in alternating hot and cold aisles.
- Blanking Panels: Install blanking panels in every open bay to prevent hot air recirculation.
- Air Dams: Install air dams to block hot air from slipping around the sides of mounted components.
- CRAC Placement: Position precision Computer Room Air Conditioners (CRAC) at the ends of hot aisles.
Space Allocation, Cable Management, and Access Floors
- Space Allocation: Support equipment like HVAC, UPS, and generators should ideally be located outside the production floor to free up valuable space.
- Cable Management: Careful planning is needed to avoid blocking airflow, especially under raised floors. Overhead cable management is becoming more common to ensure unrestricted airflow and easier access.
- Access Floors: The choice of access floor (raised floor) is critical for cooling, equipment support, and cable distribution. Factors like seismic requirements, load capacity, and panel strength must be considered.
Section 3: Data Center Infrastructure Considerations
Racks, Cabinets, and Support Infrastructure
This section covers the selection of racks, enclosures, and cable pathways, emphasizing support for climate control, power and cable management, and security. Redundancy and path diversity are critical for achieving high availability, as highlighted by the concept of "five nines" (99.999%) reliability.
Choosing the Appropriate Cabling Media
A key decision is the choice between copper and fiber cabling. The guide provides a balanced analysis:
Copper Considerations:
- The guide notes that ANSI/TIA-942 recommends ANSI/TIA Category 6/ISO Class E as the minimum for data centers, with Category 6A/ISO Class EA recommended for 10GBASE-T.
- Category 5 and 5e are not recommended for new data center installations.
- Copper offers lower initial electronics cost and flexibility for short links.
The Case for Fiber:
- Fiber offers advantages in bandwidth, distance, immunity to EMI/RFI, and space savings.
- Preterminated fiber solutions can provide up to 75% faster installation compared to field-terminated systems.
- Laser optimized 50-micron/ISO OM3 fiber is generally recommended for storage area networks (SANs) and high-bandwidth applications.
- The guide notes that the cost of a high-quality copper channel is now economically equivalent to a fiber solution, making fiber a more compelling choice.
Cable Types and Construction
The guide discusses the importance of cable construction for fire safety:
- Limited Combustible Cable (LCC) offers superior fire and smoke performance compared to standard CM, CMR (riser), or CMP (plenum) cables, making it an attractive choice for data centers.
- Low-Smoke Halogen-Free (LSZH) cables are also specified in many regions to limit toxic fumes and smoke.
Power Cables and Accessories
This section covers the selection of power cables based on:
- NEC and Local Codes: In the U.S., installations must comply with the NEC (NFPA 70) or the Canadian Electrical Code (CSA C22.1).
- Cable Tray Ratings: Cables installed in trays must meet specific fire test requirements (e.g., UL "For CT Use" rating).
- Conductor Sizing: Based on ampacity, voltage drop, and efficiency considerations.
- Stranding: The guide distinguishes between Class B (standard) and Class I (flexible) stranding, noting that Class I has a larger diameter and requires specific "flexible" lugs.
- Backup Systems: It emphasizes the need to integrate primary electrical systems with UPS, battery, and generator backup systems.
Intelligent Infrastructure Management (IIM)
The guide introduces the concept of IIM as a way to manage increasingly complex networks. It notes that manual infrastructure management is insufficient to achieve the goal of high-availability "on demand" networks. IIM systems provide real-time visibility into the physical layer, enabling better asset utilization, business resiliency, and security.
KVM Switches
The guide mentions KVM (Keyboard, Video, Mouse) switches as a tool for managing multiple servers from a single console, saving space and improving operational efficiency in the data center.
Section 4: Best Practices for Data Centers – Standards and Associations
ANSI/TIA-942 (Data Center Standard)
This is the key standard for data center infrastructure. The guide covers its guidance on:
- Topology: Hierarchical star architecture is recommended.
- Hot and Cold Aisles: Minimum aisle widths and layout recommendations for cooling.
- Tier Levels: The Uptime Institute’s Tier Classification (I-IV) is incorporated into the standard, outlining levels of redundancy and fault tolerance.
- Cabling: Recommendations for Category 6 (copper) and laser optimized 50-micron fiber (OM3).
Other Relevant Standards
The guide lists numerous other standards, including:
- IEEE 802.3an (10GBASE-T): The standard for 10 Gigabit Ethernet over copper.
- IEEE 802.3af/at (PoE): Power over Ethernet standards.
- ANSI/TIA-569-B: Pathways and Spaces.
- ANSI/TIA-606-A: Administration (labeling).
- J-STD-607-A: Grounding and Bonding.
- LEED: A green building certification program.
Section 5: Key Considerations for Deploying Data Center Solutions
This final section emphasizes the importance of supply chain management for data center projects. It explains how a total cost of ownership model, considering factors like material management and logistics, can reduce overall project costs and timelines. The guide highlights Anixter’s own supply chain solutions as a means to streamline the procurement and delivery of complex data center infrastructure.
Conclusion: A Trusted Reference for Data Center Design
Anixter’s Data Center Infrastructure Resource Guide is a valuable and practical resource for anyone involved in the design, construction, or management of a data center. By compiling essential information on standards, best practices, and key technologies, the guide provides a solid foundation for making informed decisions that ensure reliability, performance, and scalability. Its systematic approach to topics like cable media selection, power distribution, thermal management, and redundancy helps professionals navigate the complexities of building the nerve centers of the modern economy.
Download the Full Guide
This overview is based on Anixter’s comprehensive guide. The full document provides a much deeper dive into each topic, including more detailed explanations of standards, in-depth analysis of cabling options, and practical guidance on supply chain management for data center projects.
The guide is available to download for free from the provided link:
Download the Data Center Infrastructure Resource Guide (PDF)
Disclaimer: This article provides a summary of a third-party technical publication. While efforts have been made to accurately represent the content, please refer to the official Anixter document for complete technical details. Final design decisions should be made by qualified professionals.
Related Articles

Circuit Breakers for Direct Current Applications
Aug 1, 2026 · 9 min read
Direct current, which was once the main means of distributing electric power, remains widespread today in electrical plants supplying particular industrial applications. The advantages offered by the use of DC motors and supply through a single line make direct current supply a good solution for railway and…

Guide to Low Voltage Circuit Breaker Standards
Jul 19, 2026 · 7 min read
Low voltage circuit-breakers are fundamental components of every electrical installation, providing essential protection against overcurrents and short circuits. However, selecting the correct circuit-breaker for a specific application requires navigating a complex landscape of standards, each designed for different…

Mastering Medium Voltage Design
Jul 19, 2026 · 4 min read
Medium voltage (MV) electrical distribution is a critical backbone of modern infrastructure, powering everything from industrial plants and data centers to commercial buildings and utilities. Designing, installing, and maintaining these networks requires a deep understanding of complex technical standards, safety…

Power Suite A Comprehensive Digital Ecosystem for Power Generation Professionals
Jul 19, 2026 · 5 min read
The design and specification of power generation systems is a complex, multi-faceted engineering challenge. It requires precise calculations for equipment sizing, careful selection of components, and access to a vast library of technical data. For specifying engineers, contractors, and consultants, having the right…

Understanding Generator Set Ratings
Jul 19, 2026 · 9 min read
Generator set ratings may seem complex, but their basic purpose is simple: to fit the application needs at the optimum reliability, performance, and cost. An improper rating means either buying more capacity than needed or risking shorter life to overhaul, more repairs, and more downtime. The key to choosing the right…

Understanding Generator Set Load Factor: Implications for Performance and Longevity
Jul 19, 2026 · 6 min read
Generator sets (gensets) are critical assets in many facilities, providing emergency backup power or serving as the primary source of electricity in off-grid locations. However, selecting and operating a genset is not simply a matter of matching the nameplate rating to the peak load. One of the most important—and…

Understanding HTM 06-01: Electrical Services Supply and Distribution in Healthcare
Jul 19, 2026 · 6 min read
In the complex environment of a modern healthcare facility, the reliability of the electrical power supply is not just a matter of convenience—it is a matter of life and death. Healthcare premises are increasingly dependent on electrical power to maintain a safe environment, support sophisticated medical equipment…

Mastering Power Factor Correction: A Comprehensive Guide to Power Quality
Jul 19, 2026 · 7 min read
In modern electrical installations, power quality is not just a technical concern—it is a financial and operational imperative. Poor power factor leads to higher energy costs, reduced system capacity, increased losses, and potential penalties from utility companies. For engineers, facility managers, and electrical…

Engine Room Ventilation: A Practical Guide for Generator and Power System Installations
Jul 19, 2026 · 8 min read
Proper engine room ventilation is one of the most critical yet often overlooked aspects of installing and operating diesel generator sets, compressor units, and other engine-driven equipment. An inadequately ventilated engine room can lead to reduced performance, shortened equipment life, safety hazards, and…

Navigating the AI-Driven Data Center
Jul 19, 2026 · 5 min read
Artificial intelligence is no longer a futuristic concept—it is the dominant force reshaping the data center landscape today. The rapid evolution of technologies, infrastructures, and architectures for AI is being felt across the entire ecosystem, from massive "AI factories" to enterprise data centers and edge…

Mastering Modern Lighting Design: A Guide to the SLL Lighting Handbook (2018)
Jul 19, 2026 · 8 min read
Lighting is one of the most fundamental elements of the built environment. It shapes how we see, feel, and interact with the spaces we occupy—whether at work, at home, in healthcare facilities, or in public spaces. Good lighting design enhances productivity, improves wellbeing, supports safety and security, and can…

Understanding and Mitigating Harmonics with AC Drives
Jul 19, 2026 · 5 min read
Harmonic distortion is a growing concern in modern electrical installations. As facilities become increasingly reliant on non-linear loads—such as variable speed drives, computers, electronic lighting, and UPS systems—the quality of the power supply can be significantly degraded. This "electrical pollution" can lead…

Understanding Discrimination with LV Power Circuit-Breakers
Jul 19, 2026 · 4 min read
In any electrical installation, loads are connected to power sources through a succession of protection, isolation, and control devices. When a fault occurs, the primary goal is to disconnect only the faulty part of the network while keeping the rest of the installation energised. This principle is known as…

Fuseology The Fundamentals of Overcurrent Protection
Jul 19, 2026 · 7 min read
Overcurrent protection is the cornerstone of electrical system safety and reliability. Fuses have served as the "safety valve" of electrical circuits for over a century, providing a simple yet highly effective means of protecting conductors, equipment, and personnel from the destructive effects of overloads and…

Understanding Low Voltage Busbar Trunking Systems: A Modern Approach to Power Distribution
Jul 19, 2026 · 5 min read
Modern electrical installations demand solutions that balance reliability, adaptability, cost-effectiveness, and safety. The Low Voltage Busbar Trunking System (BTS) has emerged as a superior alternative to traditional cable installations in many applications. The authoritative BEAMA Guide to Low Voltage Busbar…

The Role of Isolation Transformers in Data Center UPS Systems
Jul 19, 2026 · 5 min read
Every data center power system includes transformers, but their role has evolved significantly over the past 40 years. Modern uninterruptible power supply (UPS) systems have moved away from the bulky internal transformers found in older designs, offering substantial improvements in efficiency, weight, size, and cost…

Data Centre Application Guide: A Roadmap to Building Future Ready Facilities
Jul 17, 2026 · 2 min read
Designing and building a modern data centre is a complex undertaking. It requires balancing high-performance infrastructure, strict reliability standards, and growing pressure for sustainability. The Data Centre Application Guide from Wesco Anixter is a free, solution-oriented resource designed to help contractors…

Application and Installation Guide for Generator Sets
Jul 17, 2026 · 5 min read
Designing and installing a reliable generator set installation requires careful consideration of standards, regulations, room layouts, fuel systems, exhaust, cooling, and electrical connections. Cummins Power Generation’s Application and Installation Guide for Generator Sets is a comprehensive reference document that…

The UPS Handbook: A Comprehensive Guide to Power Protection from Eaton
Jul 17, 2026 · 5 min read
Uninterruptible Power Supplies (UPS) are critical components in modern electrical infrastructure, protecting everything from small office computers to large data centers from the nine common power problems that can cause data loss, hardware damage, and costly downtime. Eaton’s UPS Handbook is a comprehensive guide…

Comparing Data Center Power Distribution Architectures
Jul 17, 2026 · 6 min read
The rapid evolution of IT equipment has fundamentally changed how power needs to be delivered in modern data centers. Traditional distribution architectures, developed decades ago, often struggle to meet the demands of high density, frequent equipment refreshes, and the need for flexibility. Schneider Electric’s White…

Protection Criteria for Medium Voltage Networks
Jul 17, 2026 · 6 min read
Designing a reliable and safe medium voltage (MV) distribution network requires a deep understanding of fault currents, network configurations, and the protection systems that safeguard both equipment and personnel. ABB’s technical guide, "Protection Criteria for Medium Voltage Networks," is an essential resource for…

A Free Power Distribution Planning Ecosystem
Jul 17, 2026 · 2 min read
For electrical engineers and consultants, planning a power distribution system is a complex task requiring careful consideration of network dimensioning, equipment selection, and regulatory compliance. Siemens addresses this challenge with the SIMARIS Suite, a comprehensive and free set of planning tools designed to…

Load Bank Utilization in Data Centers
Jul 17, 2026 · 4 min read
In the data center industry, power reliability is paramount. A facility with 99% uptime—which sounds impressive—still experiences nearly 88 hours of downtime per year. For larger data centers, where a single minute of downtime can cost an average of $7,900 USD, ensuring every electrical component operates flawlessly…

Free Professional Cable Sizing Tool
Jul 17, 2026 · 3 min read
Correctly sizing electrical cables is a fundamental task in building services engineering. An undersized cable leads to overheating, voltage drops, and potential fire hazards, while an oversized cable results in unnecessary capital expenditure. To address this challenge, Prysmian Group, a world leader in the cable…

Optimized MV Generator Power Plant Architectures for Large Data Centers
Jul 17, 2026 · 6 min read
For large data centers exceeding 5 MW, the design of the electrical distribution system and backup power supply represents a significant capital investment. One of the most impactful decisions is how to configure the generator power plant—the heart of the facility’s emergency power system. A new white paper from…

Overcurrent Protection Handbook
Jul 17, 2026 · 4 min read
Overcurrent protection is the cornerstone of electrical safety in any building. The correct selection and application of protective devices ensures not only the safety of personnel but also the reliability of the electrical system and the protection of valuable equipment. Eaton’s Bussmann series Selecting Protective…

Free Solar PV String Sizing Tool
Jul 17, 2026 · 3 min read
Designing a photovoltaic (PV) system requires careful calculation to ensure that the solar panels and inverter are perfectly matched. One of the most critical steps is determining the correct string size — the number of solar panels connected in series to an inverter’s MPPT (Maximum Power Point Tracking) input. An…

The Building Services Design Process
Jul 17, 2026 · 5 min read
Designing and delivering building services for a building is a complex, multi-stage process requiring collaboration among architects, engineers, contractors, and clients. The RIBA Plan of Work is the standard framework used in the UK and internationally to structure this process.
Join the EBSP Newsletter
Weekly industry news, the latest articles, and engineering updates — straight from practicing electrical engineers. No spam, unsubscribe anytime.