Calculations,  Switchgear,  Low Voltage,  Software

Bussmann Series FC2 Available Fault Current Calculator: A Powerful Tool for Electrical Safety and Compliance

Bussmann Series FC2 Available Fault Current Calculator: A Powerful Tool for Electrical Safety and Compliance

Introduction

In modern electrical design and safety, understanding the maximum available fault current at various points in an electrical system is non-negotiable. It is a critical parameter that directly influences the selection of overcurrent protective devices, the short-circuit current rating (SCCR) of equipment, and the overall safety of the installation. The National Electrical Code (NEC) has long mandated that equipment intended to interrupt current at fault levels must have an interrupting rating sufficient for the available fault current at its line terminals, in accordance with NEC 110.9.

Since the 2011 edition, the NEC has also required a field marking on service equipment in other than dwelling units, indicating the maximum available fault current and the date the calculation was performed. This requirement, found in NEC 110.24(A), has significantly increased the awareness of fault current values among contractors, engineers, and inspectors. It ensures that the proper interrupting ratings and short-circuit current ratings are maintained, helping to prevent catastrophic equipment failures and enhance electrical safety.

To meet these critical design and compliance needs, Eaton's Bussmann series has developed the FC2 Available Fault Current Calculator, an innovative tool designed to simplify and accelerate the process of performing point-to-point fault current calculations.

The Challenge of Fault Current Calculations

Fault current calculations, while fundamental, can be complex and time-consuming. The basic point-to-point method involves determining the impedance of various system components—transformers, conductors, busway—and using them to calculate the maximum current available at a fault location. The method involves several steps:

  1. Determine Transformer Full-Load Amps (FLA): Based on the transformer's kVA rating and secondary voltage.
  2. Find the Transformer Multiplier: Using the transformer's percent impedance (%Z) from the nameplate.
  3. Calculate Transformer Secondary Fault Current: This is the available fault current at the transformer terminals.
  4. Calculate the "f" Factor: This accounts for the impedance of the conductors between the transformer and the fault point. The formula depends on the type of fault (three-phase, line-to-line, or line-to-neutral) and uses the conductor length, constant (from tables), and the voltage.
  5. Calculate the "M" Multiplier: A factor used to determine the reduction in fault current over a distance.
  6. Calculate the Available Fault Current at the Point of Fault: This is the final value that must be used to verify the interrupting rating of protective devices.

The Bussmann Series FC2 Calculator: A Streamlined Solution

The FC2 Available Fault Current Calculator is an application developed by Eaton that automates this process, making it accessible and efficient for professionals in the field. It is available as a free, downloadable mobile app for Apple and Android devices, as well as an online version.

Key Features and Benefits

The FC2 Calculator offers several key features that make it an essential tool for modern electrical work:

  • Streamlined Point-to-Point Calculations: The app is designed to make point-to-point calculations easy, guiding the user through the process of entering system parameters to quickly determine fault currents.
  • Versatile Calculation Capabilities: It can calculate available fault current for both three-phase and single-phase systems, accommodating the majority of typical commercial and industrial installations.
  • NEC 110.24 Compliance: One of the most valuable features is the ability to create and email a compliant label for marking the available fault current on service equipment. This directly addresses the field marking requirement of NEC 110.24(A).
  • Fuse and Conductor Sizing: The application includes a fuse sizing guide to assist with proper selection of fuses and conductors for service, feeder, and branch circuits, integrating critical design tasks into a single workflow.
  • Professional Documentation: Users can create and share one-line diagrams and labels, simplifying communication with stakeholders and providing clear documentation for inspections and records.

A Tool for the Modern Electrician and Engineer

The FC2 calculator serves a wide range of professionals:

  • Electricians and Contractors: It provides a quick, in-field tool to verify fault current values on existing systems or during installations, ensuring that protective devices are properly rated.
  • Engineers and Designers: It accelerates the design process by performing quick calculations and generating documentation, freeing up time for more complex engineering tasks.
  • Electrical Inspectors: The app can be used to verify that the field markings on service equipment are accurate, helping to ensure code compliance.

While the FC2 Calculator is a powerful tool, it is important to remember that the data and calculations are provided "without warranty of any kind," as noted in the app's disclaimer. The final design and verification of complex systems should always be confirmed by a qualified professional engineer who can account for specific system variables like motor contributions and X/R ratios, which significantly affect asymmetric fault currents.

Conclusion

Eaton's Bussmann series FC2 Available Fault Current Calculator represents a significant advancement in making critical electrical calculations accessible and efficient. By automating the point-to-point method and integrating features for NEC 110.24 compliance, it helps ensure that electrical systems are designed and maintained with the correct interrupting ratings, enhancing both safety and reliability. It is a valuable resource for anyone involved in the electrical industry, from the field to the design office.

This article summarises key concepts from the Eaton Bussmann series FC2 Available Fault Current Calculator product page and supporting industry resources.

Access the full free online calculator here: Eaton Bussmann series FC2 Available Fault Current Calculator

The FC2 Mobile App can be downloaded for free from the Apple App Store and Google Play.

Disclaimer: This article provides a summary of the Eaton Bussmann series FC2 Available Fault Current Calculator and the context of fault current calculations. While efforts have been made to accurately represent the content, please refer to the official Eaton website and the complete End-User License Agreement for the FC2 application for comprehensive details. The calculations and information provided by the application are for guidance only. Final design, specification, and implementation decisions should be made by qualified professionals in accordance with all applicable regulations and standards.

Related Articles

Single-line diagram of a medium voltage protection scheme with relay and substation connections
Technical Guide,  Calculations,  MV Power,  Switchgear

Protection Criteria for Medium Voltage Networks

ABB’s technical guide covers MV network schemes, switching device selection, current/voltage transformers, short-circuit currents, neutral grounding, and equipment protection.

CableApp shown running on a desktop monitor, laptop, and mobile phone
Tools & Resources,  Calculations,  LV Power

CableApp: Free Professional Cable Sizing Tool from Prysmian

Prysmian’s free CableApp calculates optimal cable cross-sections for low and medium voltage installations, plus the energy savings and CO₂ reduction of sizing up. An overview of its features.

A technician installing Eaton Bussmann series overcurrent protection devices in a panel
Arc Flash,  Calculations,  Switchgear,  Technical Guide

Overcurrent Protection Handbook: Bussmann Series SPD

An overview of Eaton’s Bussmann series Selecting Protective Devices (SPD) Handbook — a 50-year-old industry reference covering fuseology, fault current calculations, selective coordination, and arc flash.

Hand using a mouse at a computer desk
Calculations,  Tools & Resources,  LV Power,  Photovoltaic

Free Solar PV String Sizing Tool: FIMER String Sizer

FIMER offers a free, web-based tool for determining the optimum string configuration for a PV module and inverter combination. An overview of how it works and the calculations behind it.

Join the EBSP Newsletter

Weekly industry news, the latest articles, and engineering updates — straight from practicing electrical engineers. No spam, unsubscribe anytime.